Analysis of Flood Control Measures for the Dombo River in Sayung Based on a 50 year Return Period Flood Discharge
DOI:
https://doi.org/10.26877/ijosbie.v7i2.1184Keywords:
cross-section capacity, flood control, flood dischargeAbstract
The Dombo Sayung River in Demak Regency is one of the rivers prone to flooding
due to increased flow discharge during the rainy season and the limited capacity of the river
cross-section to accommodate water flow. This study aims to analyze the capacity of the Dombo
Sayung River cross-sections under the 50-year return period flood discharge (Q50) of 78.96 m³/s
using HEC-RAS 6.6 software. Hydrological analysis was conducted using the Nakayasu
Synthetic Unit Hydrograph (SUH) method to determine the design flood discharge, while
hydraulic analysis was carried out using a steady flow approach at several river cross-sections,
namely STA 0, STA 29, and STA 60 (Dam 60). The simulation results indicate that at STA 0,
the water surface elevation increased significantly but remained within the river cross-section
capacity, indicating relatively safe conditions. At STA 29, the water level approached the
riverbank elevation, indicating a critical condition with a high potential for overflow due to
additional discharge caused by extreme rainfall or river sedimentation. Meanwhile, at STA 60
(Dam 60), the river cross-section was still relatively capable of accommodating the 50-year
return period flood discharge, although an increase in water level was observed during the
simulation. Based on these findings, flood control measures such as river normalization,
sediment dredging, embankment elevation improvement, and routine river maintenance are
required to enhance flow capacity and reduce flood risk in the Dombo Sayung River area.
References
[1] Suripin, Sistem Drainase Perkotaan yang Berkelanjutan. Yogyakarta: Andi Offset, 2004.
[2] Yudaningrum, F., & Ikhwanudin, I. (2020). Banger Retention Pool as Alternative Control Flood. International Journal of Sustainable Building, Infrastructure and Environment (IJOSBIE), 1(1).
[3] Ikhwanudin, H. Imadudin, and Y. Farida, “Design of Water Pump Station Control in Polder System using IoT and Hybrid Fuzzy Neural Network,” 2025, doi: 10.1088/1755-1315/1321/1/012014.
[4] S. Harto, Analisis Hidrologi. Jakarta: Gramedia Pustaka Utama, 2000.
[5] B. Triatmodjo, Hidrologi Terapan. Yogyakarta: Beta Offset, 2008.
[6] U.S. Army Corps of Engineers, “HEC-RAS Hydraulic Reference Manual, Version 6.6,” Hydrologic Engineering Center, 2021. [Online]. Available: https://www.hec.usace.army.mil/software/hec-ras/documentation.aspx
Downloads
Published
Issue
Section
License
Copyright (c) 2026 International Journal of Sustainable Building, Infrastructure and Environment (IJOSBIE)

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
International Journal of Sustainable Building, Infrastructure and Environment (IJOSBIE) are published under the terms of the Creative Commons Attribution-ShareAlike. Authors retain the copyright to their work. Users may read, copy and distribute the work in any medium provided the authors and the journal are appropriately credited.
.png)